Tempstar w/ S8600M ignition problem - DoItYourself.com
2010年2月13日 · Gas and Oil Home Heating Furnaces - Tempstar w/ S8600M ignition problem - 19 year old Tempstar 867769446 NUGK125DK07 nat. gas furnace with Honeywell S8600M Controller located in Salt Lake City, currently 39 deg F: Good morning: Looking for suggestions on the following: 1) Thermostat calls for heat.
Install of Honeywell S8600M control - DoItYourself.com
2006年10月21日 · Gas and Oil Home Heating Furnaces - Install of Honeywell S8600M control - I have been having trouble with the spark ignition on my furnace. Not sure what the problem is, but need to wiggle the spark wire to get the furnace to fire up. I'm going to go ahead and replace the control module -- it's a Honeywell S8600M. I'm
Defective Honeywell S8600M? - DoItYourself.com Community …
2008年4月18日 · Gas and Oil Home Heating Furnaces - Defective Honeywell S8600M? - I have an old Raypak Versa natural gas spa heater (model C-335B). I just replaced the ignition control with a Honeywell S8600M and the gas valve with a Honeywell VR8304K. The S8600M is stamped ’90 second start’ on the case. On a cold start, the pilot
Bad Honeywell S8600 Ignition Module? - DoItYourself.com
2009年3月28日 · Gas and Oil Home Heating Furnaces - Bad Honeywell S8600 Ignition Module? - I have a Heil gas furnace (vintage 1992).
Honeywell s8600m. furnace just makes a click sound every 5 …
2012年1月8日 · Gas and Oil Home Heating Furnaces - Honeywell s8600m. furnace just makes a click sound every 5 second but no heat - Appreciate if someone can help me here. My furnace on my roof was working fine until one morning we just started hearing a clicking sound. Its probably the inginition. When we turn on the thermostat and
Honeywell s8600m hot water heater not igniting pilot light
2013年1月3日 · I have a hot water heater that is controlled by a s8600m continuous try ignition. the blower comes on like normal but I don't hear the usual "ticking" of the pilot light igniter and so no pilot light or main burner. All wires and contacts seem good. In fact the whole unit seems in good shape for 9 years old. cold and bummed in Boise.
Furnace Won't Turn On - Intermittent Problem - DoItYourself.com
2013年2月25日 · Ignition MOdule: Honeywell S8600M Fan Timer/Furnace Control: Honeywell ST9120G4004 Fuel: Natural Gas Thermostat: Hunter 44155C (electronic programmable) Batteries were replaced on thermostat about one month ago. Problem started 4 days ago. Area: Denver, Colorado. Outside Temp: 30-40 day, 10-20 night.
Honeywell S8600M stop igniting after a few hours
2010年12月20日 · Gas and Oil Home Heating Furnaces - Honeywell S8600M stop igniting after a few hours - Hey folks, I have a Carrier natural gas heating system which was installed in 2001 and has problem recently. The equiptment is as below: Dunkirk Boiler PWB-5D Boiler Honeywell S8600m1013 ignition module Honeywell Aquasat Relay TYPE
No spark, no heat - DoItYourself.com Community Forums
2008年1月28日 · The furnace uses a Honeywell S8600M ignition module. A few days ago there were a few instances where the main blower would not turn off. Cold air was coming from the registers, but when I cycled the main power on the furnace the blower fan turned off. Any advice would be most appreciated.
UTICA BOILER with auto light WILL NOT FIRE UP?
2006年11月22日 · Gas fired Hot water system with 3 zones--each zone has it's own pump. When the main floor calls for heat, the pump runs but the boiler does not fire. when another floor calls for heat as well, the boiler does fire, and both floors get heat.